A telecom generator generally refers to a diesel generator set that provides emergency or backup power to communication stations in a telecommunications system.
I. Features of Telecom Generators
Telecom generators are specifically designed for communication equipment and feature high reliability, stable voltage and frequency, low harmonic distortion, and fast automatic start. They can provide continuous backup power for base stations, data centers, and other facilities during power outages.
II. Huaquan Power is a professional telecommunications generator manufacturer in China
Huaquan Power Company was established in 2010. The company's industries cover power generation equipment, new energy storage equipment, high and low voltage complete sets of equipment, and power engineering, among other fields. It has also developed three major brands: "HQ-POWER," "HUAQUAN," and "Huaquan." Currently, the company has grown into a strong global brand in the power industry, with cumulative global sales exceeding 1 million units.
III. Advantages of Telecom Generators
1. Reliability and Stability of Power Supply
Telecom generators strictly follow communication industry standards, with rigorous requirements for components, manufacturing processes, and testing to ensure long-term stable operation. Voltage and frequency fluctuations are minimal, waveform distortion (harmonics) is low, providing "clean" electricity.
2. Fast Emergency Response Capability
Telecom generators are usually paired with ATS (Automatic Transfer Switches), allowing them to automatically start, establish voltage, and switch power supply within a few seconds after a utility outage, minimizing communication downtime. They support remote monitoring and management, enabling automated operation and reducing reliance on manual intervention.
3. Strong Environmental Adaptability and Durability
Telecom generators are designed to operate reliably in various harsh environments, both outdoors and in simple equipment rooms.
4. Strong Continuous Operation Capability: They can meet the continuous power supply needs of communication base stations and data centers during prolonged outages, ensuring uninterrupted network operation.
5. Professional Compatibility and Maintainability
Telecom generators are optimized for communication loads, featuring high load capacity and minimal starting impact. Their structural design considers the space constraints of communication equipment rooms, provides clear maintenance access, uses standardized spare parts, and allows for convenient maintenance.
IV. Long-term Storage Precautions for Telecom Generators
1. Before storage, the telecom generator should be thoroughly cleaned to remove dust and oil stains from its exterior. Check for any obvious damage to the generator and clear away surrounding debris. For the fuel and lubrication systems, it is recommended to drain old fuel from the tank and replace it with new, high-quality engine oil up to the specified level. Additionally, drain the coolant from the radiator and apply anti-rust treatment to the generator. For the electrical system, carefully check the battery charge status, clean terminal oxidation, and ensure all connections are secure. To prevent natural battery discharge, disconnect the battery from the starter motor.
2. Storage Environment Requirements for Telecom Generators
Choose a separate, well-ventilated, dry, and clean location, avoiding excessive heat, cold, rain, or direct sunlight. For communication base stations, it is best to store the generator inside the equipment room. If stored outdoors, ensure the protective rating is met and take extra measures to prevent rain and dust. The storage location should be away from flammable and explosive materials and be equipped with fire-fighting measures such as ABC fire extinguishers.
3. Regular Maintenance During Storage of Telecom Generator
During long-term storage, regular maintenance is required. It is recommended to fully charge batteries with electrolyte every 5 to 8 weeks. Check and place desiccants to absorb moisture, seal air intakes, and cover exhaust outlets with oiled paper to prevent dust and moisture from entering the generator. Biological protection should also be considered.
4. Necessary Checks Before Starting the Telecom Generator
If the telecom generator has been idle for a long time and needs to be used for emergency purposes, checks must be performed before starting. First, check the fuel, engine oil, and coolant levels and quality. Next, manually or electrically rotate the crankshaft 2-3 times to feel for any sticking. After connecting the power, attempt a trial start. If starting is difficult, do not repeatedly force it; first check the battery voltage and fuel supply system for issues.
V. Q&A on Knowledge Related to Telecom Generators
1. What checks should be performed while a telecom generator is operating?
Regularly inspect parameters such as the generator's sound, vibration, temperature, voltage, current, and frequency, as well as the working condition of brushes and the excitation system.
2. How can damage to a telecom generator be prevented during storage?
Before storage, drain the old fuel, replace with new engine oil, and carry out rust prevention measures; the storage environment should be dry, ventilated, and at an appropriate temperature; the battery should be charged regularly, and the generator should be manually rotated.
3. What are the grounding requirements for a telecom generator?
The frame and enclosure of the telecom generator must be connected to a protective ground, and the neutral line of a three-phase four-wire output must also be grounded. The grounding resistance should be less than 10 ohms, and the cross-sectional area of the ground wire should not be smaller than that of the generator output wire.
VI. Application Areas of Telecom Generators
1. Industrial Production and Construction: Telecom generators can provide power support for equipment on industrial production lines and temporary equipment at construction sites.
2. Energy and Resource Extraction: They offer necessary power supply in harsh environments or areas not covered by the grid, such as isolated islands, offshore drilling platforms, coal mines, and oil fields.
3. Medical and Emergency Disaster Relief: Telecom generators can supply power to critical medical equipment during outages and serve as an important power source for disaster relief sites.
4. Commercial and Public Services: They provide backup power for key equipment like computer servers in office buildings and small shops, ensuring business continuity.
5. Agriculture and Special Activities: They can be used to power irrigation systems in farmland or provide electricity for outdoor activities and film shoots far from the city grid.
Telecom generators have a wide range of applications, primarily serving as backup power to ensure the stable operation of critical infrastructure. Users should choose the appropriate telecom generator based on specific work needs.
More information about telecom generators: http://www.wf-fadianji.com/
Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD